Edimax ES-5224R+ Manuel d'utilisateur Page 172

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 265
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 171
User Manual
Publication date: July, 2006
Revision A2
166
logout
Syntax:
logout
Description:
When you enter this command via Telnet connection, you would logout the system
and disconnect. If you connect the system through direct serial port with RS-232
cable, you would logout the system and be back to the initial login prompt when you
run this command.
Argument:
None.
Possible value:
None.
Example:
# logout
restore default
Syntax:
restore default
Description:
When you use this function in CLI, the system will show you the information “Do you
want to restore the default IP address?(y/n)”. If you choose Y or y, the IP address
will restore to default “192.168.1.1”. If you choose N or n, the IP address will keep
the same one that you had saved before.
If restoring default successfully, the CLI would prompt if reboot immediately or not. If
you press Y or y, the system would reboot immediately; otherwise, it would be back
to the CLI system. After restoring default configuration, all the changes in the startup
configuration would be lost. After rebooting, the entire startup configuration would
reset to factory default.
Argument:
None.
Possible value:
None.
Example:
# restore default
Do you want to restore the default ip address?(y/n)
Restoring ...
Restore default configuration successfully.
Do you want to reboot the system?(y/n)