57
3-2-4. Detail Counter
The function of Detail Counter collects any information and provides the
counting about the traffic of the port, no matter the packet is good or bad.
In the Fig. 3-14, the window can show only one port counter information at
the same time. To see another port’s counter, you have to pull down the list of
Select, then you will see the figures displayed about the port you had chosen.
Each data field has 20-digit long. If the counting is overflow, the counter will
be reset and restart counting. The data is updated every time interval defined by the
user. The valid range is 3 to 10 seconds. The Refresh Interval is used to set the
update frequency. Default update time is 3 seconds.
Fig. 3-14
Function name:
Detail Counter
Function description:
Display the detailed counting number of each port’s traffic. In the Fig. 3-14, the
window can show all counter information of each port at one time.
Parameter description:
Rx Packets:
The counting number of the packet received.
Rx Octets:
Total received bytes.
Rx Errors:
Vue de la page 62